Our Technology
Power Distribution Unit (PDU)
Factory-integrated power distribution. Engineered for your application. Built for faster deployment.
One Integrated Architecture. Multiple deployment configurations.
AK Power Solutions Power Distribution Units bring power transformation, protection, controls, and distribution together in one factory-integrated system. Engineered around project-specific electrical, site, and deployment requirements, each configuration helps reduce field integration complexity and supports more predictable installation.
Built for Better Project Outcomes
Move complexity from the field to the factory. Our integrated approach simplifies installation, reduces on-site coordination, and supports more predictable execution.
Faster Deployment
Reduced Field Complexity
Factory-Tested Performance
Incoming Power & Protection
Receives, protects, and isolates incoming power while coordinating protection at the system entrance.
Voltage: Up to 34.5 kV
Voltage Class: Up to 38 kV
Connection: Delta | Wye | Grounded Wye
Input Connection: Radial | Loop
Protection & Sensing: CTs | PTs | Arresters | CPT
Transformer
Apparent Power: 112.5 – 5,000 kVA
Phase: 1 | 3
Frequency: 50 – 60 Hz
Winding Material: Aluminum (Al) | Copper (Cu)
Connection: Delta | Wye | Grounded Wye
Connection Type: Flush | Throat
Taps: ±2 @ 2.5% Standard
Impedance: 5.75% ±7.5% Standard
Liquid-Filled Options
HV BIL: 30 – 250 kV
LV BIL: 30 – 75 kV
Temperature Rise: 55C | 65C | 55/65C
Tank Construction: Sealed
Oil Type: Natural Ester | Mineral Oil
Mineral Oil: ONAN | ONAF | ONANONAF
Natural Ester: KNAN | KNAF | KNAN/KNAF
Dry-Type Options
HV BIL: 100 – 200 kV
LV BIL: 10 – 45 kV
Temperature Rise: 80C | 115C | 150C
Insulation Class: H
Type: Cast Resin | VPI
Cooling Class: AA | AF | AA/AF
Controls & Integration
Protection: Arresters | Fuses | Switch
Control Power: CPT Available
Thermal Management: Heaters | Fans
Monitoring: CTs | PTs
Certification: UL | cUL | DOE
Controls & Integration
Protection: Arresters | Fuses | Switch
Control Power: CPT Available
Thermal Management: Heaters | Fans
Monitoring: CTs | PTs
Certification: UL | cUL | DOE
Low-Voltage Distribution (Switchboard)
Voltage: 480 – 1,000 V
Voltage Class: Up to 5 kV
Main: Up to 6,000 AF
Service Disconnects: Up to 6
Connection: Delta | Wye | Grounded Wye
Output Configuration: Radial
Feeder Sections: Configured to customer requirements
Same Architecture. Different Deployment.
The core power architecture remains integrated. The enclosure, equipment arrangement, and deployment format are configured around site and application requirements.

Power Distribution Unit
Enclosure: Purpose-built integrated enclosure.
Configuration: Factory-integrated equipment arranged around product requirements.
Deployment: Application-specific footprint and installation.

ISO Container PDU
Enclosure: 20 ft or 40 ft ISO Container.
Configuration: Factory-integrated equipment within a standardized container format.
Deployment: Transportable, stackable configuration supporting site planning and placement.

Skid-Mounted PDU
Enclosure: No common outer enclosure.
Configuration: Integrated equipment mounted on a structural skid.
Deployment: Open equipment arrangement with direct component access.
Built for Real-World Deployment
EV Charging
Data Centers
Renewable Energy
Industrial & Manufacturing
Commercial Infrastructure